NIR Near Infrared
Fiber Optic Spectrometers
Installation and Operation Manual
Document Number 197-00000-512-02-0707
Offices:
Ocean Optics, Inc. World Headquarters
830 Douglas Ave., Dunedin, FL, USA 34698
Phone 727.733.2447
Fax 727.733.3962
8 a.m.– 8 p.m. (Mon-Thu), 8 a.m.– 6 p.m. (Fri) EST
E-mail: [email protected] (General sales inquiries)
[email protected] (Questions about orders)
[email protected] (Technical support)
Vista de pagina 0
1 2 3 4 5 6 ... 35 36

Indice de contenidos

Pagina 1 - NIR Near Infrared

NIR Near Infrared Fiber Optic Spectrometers Installation and Operation Manual Document Number 197-00000-512-02-0707 Offices: Ocean Opt

Pagina 2

1: Introduction 4 197-00000-512-02-0707

Pagina 3 - Table of Contents

Chapter 2 Installing the NIR Spectrometer Overview You must install the operating software application prior to connecting the NIR Spectrometer to th

Pagina 4

2: Installation 4. Insert the square end of the cable into the rear of the NIR Spectrometer, and then insert the rectangular end into the USB port

Pagina 5 - About This Manual

2: Installation Configuring the NIR Spectrometer The NIR spectrometer can be used with either SpectraSuite or OOIBase32 software when connected to

Pagina 6 - Service

2: Installation If you do not have web access, you can retrieve this document from the Software and Technical Resources CD included with your spectr

Pagina 7 - Introduction

2: Installation Control Description Enable Periodic Update Check this box to enable periodic update of the NIR detector temperature controls. Update

Pagina 8 - About the Modular Approach

2: Installation 10 197-00000-512-02-0707

Pagina 9 - Items Included with Shipment

Chapter 3 Troubleshooting Overview The following sections contain information on troubleshooting issues you may encounter when using the NIR Spectrom

Pagina 10 - 1: Introduction

3:Troubleshooting Remove the Unknown Device from Windows Device Manager ► Procedure 1. Open Windows Device Manager. Consult the Windows operating

Pagina 11 - Overview

3: Troubleshooting 3. Delete the OOI_USB.INF in the INF directory. If your computer is running either the Windows 2000 or XP operating system, you m

Pagina 12 - Serial Port Mode

Additional Offices: Ocean Optics Asia 666 Gubei Road, Kirin Tower, Suite 601B, Changning District, Shanghai, PRC. 200336 Phone 86.21.5206.8686 Fax

Pagina 13 - External Triggering Options

3:Troubleshooting Operating System Instructions Windows 2000 1. Select Start | Settings | Control Panel | System 2. Select the Hardware tab 3. Clic

Pagina 14 - NIR Controls

Appendix A Calibrating the Wavelength of the NIR Spectrometer This Appendix describes how to calibrate the wavelength of your spectrometer. Though ea

Pagina 15 - NIR Toolbar in OOIBase32

A: Calibrating the Wavelength of the Spectrometer • A light source capable of producing spectral lines. Ocean Optics’ AR-1 Argon lamp or HG-1 Mer

Pagina 16 - 2: Installation

A: Calibrating the Wavelength of the NIR Spectrometer Independent Dependent Values compute

Pagina 17 - Troubleshooting

A: Calibrating the Wavelength of the Spectrometer 7. Record the Intercept as well as the First, Second, and Third Coefficients. Also, look at the

Pagina 18 - Manager

A: Calibrating the Wavelength of the NIR Spectrometer 12. Repeat Step 12 for all of the new values. 13. Click on the Save All Values button to sav

Pagina 19 - Linux Operating Systems

A: Calibrating the Wavelength of the Spectrometer 20 197-00000-512-

Pagina 20 - 3:Troubleshooting

Appendix B Specifications How the Spectrometer Works Light passes through the NIR Spectrometer through a fixed optical path. The optical bench of the

Pagina 21 - Calibrating the Spectrometer

B: Specifications Name Description InGaAs Detector Each pixel on the detector responds to the wavelength of light that strikes it. Electronics bring

Pagina 22 - Procedure

B: Specifications NIR Spectrometer – Slit Size vs. Resolution and Throughput The following chart illustrates the effect that varying slit sizes have

Pagina 23

Table of Contents About This Manual ... iii Do

Pagina 24

B: Specifications NIR512 NIR256-2.1 NIR256-2.5 Optical resolution (slit dependent) 4.2 – 14.0 nm FWHM With Grating N1:4.5 – 14.0 FWHM With Grating

Pagina 25

B: Specifications Grating Efficiency Curves 9-pin RS-232 Serial Port Pinout When facing the 9-pin RS-232 Serial Port connector on the NIR Spectrom

Pagina 26

B: Specifications 15-pin Accessory Connector Pinout When facing the 9-pin RS-232 Serial Port connector on the NIR Spectrometer, the pins are numbere

Pagina 27 - Specifications

Appendix C NIR256-2.5µm Sensitivity When configuring a system for operation out to 2.5µm it is important that you consider the following details: •

Pagina 28 - NIR Detector Specifications

C: NIR256-2.5 µm Sensitivity The figure below shows the relative intensity of a NIR256-2.5 Spectrometer with a 25um slit directly coupled to an LS-1

Pagina 29 - Throughput

Index A accessories, 2 Accessories, 7 Adobe Acrobat Reader, 3 C Calibrating, 15 calibration coefficients saving in Serial mode, 19 saving in USB mode

Pagina 30 - Spectral Response Curves

Index S shipment contents, 3 Slit, 21 SMA Connector, 21 software, 2 Software and Resources Library CD, 3 Specifications Detector, 22 Spectrometer, 2

Pagina 31 - 5 Ground

Table of Contents Remove Improperly Installed Files ... 12

Pagina 32 - LED Information

About This Manual Document Purpose and Intended Audience This document provides you with instructions to get your system up and running. In addition

Pagina 33 - NIR256-2.5µm Sensitivity

1: Introduction Product-Related Documentation You can access documentation for Ocean Optics products by visiting our website at http://www.oceanopti

Pagina 34

Chapter 1 Introduction Product Description The NIR (Near Infrared) Fiber Optic Spectrometer connects to a notebook or desktop PC via a USB port. It r

Pagina 35

1: Introduction About the Modular Approach Ocean Optics fiber optic spectrometer systems are based on low-cost, modular data acquisition principles

Pagina 36 - Index

1: Introduction Interface Options Because the NIR Spectrometer has both a USB and a serial port, you can connect the NIR Spectrometer to a desktop o

Comentarios a estos manuales